2019-05-29CUSTOMER STATES THERE IS TRANSMISSION FLUID LEAKING FROM THE PAN AREA, PLEASE CHECK AND ADVISE. TECHNICIAN CHECKED AND FOUND THERE TO BE FLUID COMING FROM THE BELL HOUSING AREA. TECHNICIAN CLEANED AND ADDED DYE TO VERIFY LOCATION OF LEAK AND FOUND THERE TO BE FLUID COMING RIGHT OUT OF THE BOTTOM ROUND INSPECTION PORT OF THE BELL HOUSING. TECHNICIAN RECOMMENDS REMOVE THE TRANSMISSION AND INSPECT POSSIBLE COMPONENTS AND REPAIR. TECHNICIAN REMOVED THE TRANSMISSION AND FOUND THE TRANSMISSION FLUID DYE TO BE COMING FROM THE FRONT PUMP SEAL AREA. TECHNICIAN REMOVED THE FLUID PUMP AND REPLACED THE PUMP OUTER SEAL AND PUMP INPUT SEAL. TECHNICIAN RE ASSEMBLED AND TEST DROVE TO FIND THERE TO BE NO FURTHER LEAKS. LUKE HARRISON $0.00 