Invoice #29273 for
(Cassidy Morley)
2-758-452-2826
2006 GMC SIERRA 2500HD
Not yet Run
Writer:
None
Promotion:
None
Add New Promotion
Mileage:
PO Number:
Notes:
Change Back to an RO
More Info
Fixed Price:
Add Hazmat?:
No
Yes
Add Supplies?:
No
Yes
Quote Date:
RO Date:
Invoice Date:
Print Quote
Print RO
Print Invoice
Images
Image
Jobs
Start Date
Description
Technician
Amount
2021-06-11
A. CUSTOMER STATES THERE IS A WIRING HARNESS NEAR THE DRIVERS SIDE EXHAUST MANIFOLD THAT HAS GOTTEN TOO CLOSE TO THE MANIFOLD AND HAS MELTED. TECHNICIAN VERIFIED CONCERN AND NOTED IT TO BE POSSIBLE TO BE A RELATED TO THE PREVIOUS ENGINE REPAIRS. TECHNICIAN GAINED ACCESS TO THE HARNESS AND CUT OUT THE MELTED SECTION, SOLDER REPAIRED WIRES, APPLIED HEAT SHRINK, APPLIED WIRE LOOM, AND RE ROUTED HARNESS PROPERLY. THIS REPAIR IS BEING COVERED UNDER WARRANTY FROM CYLINDER HEAD REPAIRS.
RUSSELL HUDSON
$0.00
2021-06-11
B. CUSTOMER STATES THERE ARE MULTIPLE PLASTIC RETAINING CLIPS AND PIECES OF WIRE LOOM THAT ARE BROKEN AND OR FALLING APART. CUSTOMER HAS REQUESTED THOSE PIECES OF LOOM BE REPLACED, AND THE CLIPS BE EITHER REPLACED WHERE POSSIBLE OR OTHERWISE SECURED. THIS IS BEING DONE AT NO CHARGE AS PER CUSTOMER SATISFACTION.
RUSSELL HUDSON
$0.00
2021-06-11
C. CUSTOMER REQUEST TO MONITOR BALANCE RATES TO VERIFY IF THEY ARE WITHIN LIMITS. TECHNICIAN TEST DROVE ABOUT 5 MILES WHILE MONITORING RATES IN NEUTRAL AND IN DRIVE STOPPING OFTEN AND FOUND BALANCING RATES TO BE WITHIN SPECIFIED RANGE AT THIS TIME.
RUSSELL HUDSON
$0.00
2021-06-11
D. CUSTOMER BELIEVES THERE IS A COOLANT LEAK PRESENT THAT MAY BE INTERMITTENT, PLEASE CHECK AND ADVISE. TECHNICIAN VISUALLY INSPECTED AND FOUND NO SIGNS OF LEAKAGE. TECHNICIAN CHECKED UNDER PRESSURE AND FOUND THERE TO BE NO SIGNS OF LEAKAGE AT THIS TIME. CUSTOMER IS RECOMMENDED TO RETURN IF PROBLEM PERSISTS.
RUSSELL HUDSON
$0.00
Sub-total
$0.00
Total
$0.00
Fee
Payments
Total Payments To Date
$0.00
Balance Remaining
$0.00
View all Payments for this Invoice