Job #9705 for
HARRISON ELECTRIC (Tess Andersson)
2004 Honda 2000 WATT GENERATOR
Invoice #4496
Technician:
None
Concern:
CUSTOMER STATES GENERATOR IS LEAKING OIL AND STEP UP SWITCH IS NOT WORKING. PLEASE CHECK AND ADVISE.
Discount:
Percentage
Dollar
Repair:
TECH CHECKED AND FOUND OIL FILL PLUG SEAL THE CAUSE OF THE OIL LEAK AND FOUND STEP UP CIRCUIT RELAY HAD A LOOSE CONNECTION. REPLACED SEAL TO REPAIR LEAK, CHANGED OIL AND SPARK PLUG FOR CUSTOMER, AND TIGHTENED RELAY CONNECTION TO REPAIR STEP UP SWITCH CIRCUIT. RE-TESTED AND NOW OPERATING AS DESIGNED.
StartDate:
EndDate:
Tax this Job?
Yes
No
Parts and Labor
Description
Quantity
List
Total
Delete?
LABOR
1.50
$90.00
$135.00
X
FACTORY NGK CR5HSB SPARK PLUG
1.00
$5.84
$5.84
X
CHEVRON 10W-30
1.00
$5.99
$5.99
X
SEAL
1.00
$0.76
$0.76
X
Total
$147.59
Add a Part or Labor for this Job